Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
J. bras. pneumol ; 48(1): e20210349, 2022. tab, graf
Article in English | LILACS | ID: biblio-1360534

ABSTRACT

ABSTRACT Objective: To assess the feasibility of using a new helmet interface for CPAP, designated ELMO, to treat COVID-19-related acute hypoxemic respiratory failure (AHRF) outside the ICU. Methods: This was a proof-of-concept study involving patients with moderate to severe AHRF secondary to COVID-19 admitted to the general ward of a public hospital. The intervention consisted of applying CPAP via the ELMO interface integrated with oxygen and compressed air flow meters (30 L/min each) and a PEEP valve (CPAP levels = 8-10 cmH2O), forming the ELMOcpap system. The patients were monitored for cardiorespiratory parameters, adverse events, and comfort. Results: Ten patients completed the study protocol. The ELMOcpap system was well tolerated, with no relevant adverse effects. Its use was feasible outside the ICU for a prolonged amount of time and was shown to be successful in 60% of the patients. A CPAP of 10 cmH2O with a total gas flow of 56-60 L/min improved oxygenation after 30-to 60-min ELMOcpap sessions, allowing a significant decrease in estimated FIO2 (p = 0.014) and an increase in estimated PaO2/FIO2 ratio (p = 0.008) within the first hour without CO2 rebreathing. Conclusions: The use of ELMOcpap has proven to be feasible and effective in delivering high-flow CPAP to patients with COVID-19-related AHRF outside the ICU. There were no major adverse effects, and ELMO was considered comfortable. ELMOcpap sessions significantly improved oxygenation, reducing FIO2 without CO2 rebreathing. The overall success rate was 60% in this pilot study, and further clinical trials should be carried out in the future. (ClinicalTrials.gov identifier: NCT04470258 [http://www.clinicaltrials.gov/])


RESUMO Objetivo: Avaliar a viabilidade do uso de uma nova interface do tipo capacete para CPAP, denominada ELMO, para o tratamento da insuficiência respiratória aguda (IRpA) hipoxêmica por COVID-19 fora da UTI. Métodos: Estudo de prova de conceito envolvendo pacientes com IRpA hipoxêmica moderada a grave secundária à COVID-19, internados na enfermaria geral de um hospital público. A intervenção consistiu na aplicação de CPAP por meio da interface ELMO integrada a fluxômetros de oxigênio e ar comprimido (30 L/min cada) e a uma válvula de PEEP (níveis de CPAP = 8-10 cmH2O), formando o sistema ELMOcpap. Os pacientes foram monitorados quanto a parâmetros cardiorrespiratórios, eventos adversos e conforto. Resultados: Dez pacientes completaram o protocolo do estudo. O sistema ELMOcpap foi bem tolerado, sem efeitos adversos relevantes. Seu uso foi viável fora da UTI por tempo prolongado e mostrou-se bem-sucedido em 60% dos pacientes. Uma CPAP de 10 cmH2O com fluxo total de gás de 56-60 L/min melhorou a oxigenação após sessões de ELMOcpap de 30-60 min, permitindo redução significativa da FIO2 estimada (p = 0,014) e aumento da PaO2/FIO2 estimada (p = 0,008) na primeira hora, sem reinalação de CO2. Conclusões: O uso do ELMOcpap mostrou-se viável e eficaz no fornecimento de CPAP de alto fluxo a pacientes com IRpA hipoxêmica por COVID-19 fora da UTI. Não houve nenhum efeito adverso importante, e o ELMO foi considerado confortável. As sessões de ELMOcpap melhoraram significativamente a oxigenação, reduzindo a FIO2 sem reinalação de CO2. A taxa global de sucesso foi de 60% neste estudo piloto, e novos ensaios clínicos devem ser realizados. (ClinicalTrials.gov identifier: NCT04470258 [http://www.clinicaltrials.gov/])


Subject(s)
Humans , Respiratory Insufficiency/therapy , COVID-19 , Pilot Projects , Feasibility Studies , Proof of Concept Study , SARS-CoV-2 , Intensive Care Units
5.
Rev. bras. anestesiol ; 62(1): 111-117, jan,-fev. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-612876

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A análise processada do eletroencefalograma tornou-se de extrema importância na monitoração do sistema nervoso, sendo utilizada a fim de uma melhor adequação anestésica. O objetivo foi fazer uma revisão sobre cada um dos parâmetros processados, definindo sua real importância. CONTEÚDO: Foi realizada revisão mostrando os aspectos matemáticos, físicos e clínicos assim como suas correlações e atualizações, com apresentação de novos parâmetros integrados. CONCLUSÕES: A análise adequada dos parâmetros processados do eletroencefalograma pode proporcionar maior segurança intraoperatória assim como resultar em melhor desfecho para o paciente.


BACKGROUND AND OBJECTIVES: The processed analysis of electroencephalogram became extremely important to monitor nervous system, being used to obtain a better anesthetic adequacy. The objective was to conduct a review about each processed parameter, defining its real importance. CONTENT: A review was conducted showing mathematical, physical and clinical aspects as well as their correlations and updates, presenting new integrated parameters. CONCLUSIONS: An adequate analysis of processed parameters of electroencephalogram may provide more intraoperative safety as well as result in a better outcome for the patient.


JUSTIFICATIVA Y OBJETIVOS: El análisis procesado del electroencefalograma se convirtió en algo extremadamente importante en el monitoreo del sistema nervioso, siendo utilizado para lograr una mejor adecuación anestésica. El objetivo fue realizar una revisión sobre cada uno de los parámetros procesados, definiendo su real importancia. CONTENIDO: Se realizó una revisión mostrando los aspectos matemáticos, físicos y clínicos, como también sus correlaciones y actualizaciones, y presentando nuevos parámetros integrados. CONCLUSIONES: El análisis adecuado de los parámetros procesados del electroencefalograma, puede proporcionar una mayor seguridad intraoperatoria como también un mejor resultado para el paciente.


Subject(s)
Electroencephalography , Electromyography , Environmental Monitoring
SELECTION OF CITATIONS